4
IP1897EN • 2012-03-22
2. EC DECLARATION OF CONFORMITY
Manufacturer: DITEC S.p.A.
Address: via Mons. Ban, 3 21042 Caronno P.lla (VA) - ITALY
declares that the control panel E1T is in conformity with the provisions of the following EC directives:
EMC Directive 2004/108/EC;
Low Voltage Directive 2006/95/EC.
Caronno Pertusella, 13-12-2010 Silvano Angaroni
(Managing Director)
3. TECHNICAL DATA
3.1 Applications
NOTE: the given operating and performance features can only be guaranteed with the use of DITEC
accessories and safety devices.
4. CONNECTION OF POWER SUPPLY
Fix the control panel permanently. Pass the cables along from the lower side of the container.
Before connecting the power supply, make sure the plate data correspond to that of the mains power supply.
An omnipolar disconnection switch with minimum contact gaps of 3 mm must be included in the mains supply.
Check that upstream of the electrical installation there is an adequate residual current circuit breaker and a
suitable overcurrent cutout.
Use a H07RN-F 4G1,5 type electric cable and connect to the terminals L1, L2, L3, (yellow/green) in the
automation.
Secure the cable using the special cable clamp and remove the outer sheath near the terminal only.
Make sure there are no sharp edges that may damage the power supply cable.
Connection to the mains power supply, in the section outside the automation, is made with independent chan-
nels and separated from the connections to the control and safety devices.
E1T
Power supply 400 V~ 50 Hz
F1 fuse F8A
F2 fuse F8A
F3 fuse F8A
F4 fuse F3,15A
Motor output 400 V~ 6 A
Accessories power supply 24 V
0,5 A
Temperature min -20 °C max +55 °C
Degree of protection IP55
Box dimensions 238x357x120