7. ADJUSTMENTS
Description OFF ON
DIP1 Command 1-3 operation.
NOTE: it also sets operating mode of the
plugin cards connected on AUX1 and
AUX2.
Step-by-step. Opening.
DIP2 Restore automatic closing time. 50% 100%
DIP3 3 seconds preashing. Disabled during opening.
Enabled only with automatic
closing with TC >3 s.
Enabled for both opening
and closing.
DIP4 Application type. Sliding gate or sectional
overhead door.
DO NOT USE
DIP5 Dynamic brake. Disabled. DO NOT USE
DIP6 FUTURE USE / /
Description OFF ON
SO Reversal safety switch function. With the automation blocked,
if the contact 1-8 or 41-8 is
open, it is possible to activate
the opening operation.
With the automation blocked,
if the contact 1-8 or 41-8 is
open, any operation is im-
possible.
EO DO NOT USE / /
Trimmer Description
RP
Partial opening adjustment. From 0 to 30 s.
TC
Setting automatic closing time. From 0 to 120 s.
NOTE: after the activation of the stop command, once contact 1-9 has closed again,
the automatic closing is only activated after a total, partial or step-by-step opening
command.
LED On Flashing
17
FUTURE USE
12
0-12 limit switch contact is open.
/
11
0-11 limit switch contact is open.
/
IN
Receipt of command or change in status of
a dip-switch.
/
SA
At least one of the safety contacts is open. STOP operation activated
by push-button panel PT4.
Safety test failure on SOFA1-SOFA2
device (terminal 41).
Operations count performed (only when con-
trol panel is switched on):
= 1000 operations
= 10000 operations
POWER
Power supply on. Current overload on
ashing light output.
Shortcircuiting of
the ashing light driver.