24
8.5 Door Position
If the upper or lower door is closing too high or low against
the frame, cold air leakage can occur. Adding or deleting
a at thin washer on top of the lower or middle hinge pin
can raise or lower the door position. To correct the door
alignment, loosen the hinge screws slightly and reorient
the door in the proper position. Hold the door in its new
position and carefully retighten the hinge screws.
8.6 Ambient Temperature
This is the temperature surrounding the recreational ve-
hicle, as well as the temperature of air at the back of the
refrigerator. As the ambient temperature increases, the air
temperature in the area of the cooling unit increases. Im-
proper venting at this point will cause the cooling unit to
have reduced efciency. A refer that chases the out-side
temperature is improperly vented or has a weak cooling
unit.
Note: To form a proper seal, it is important not to leave
any gaps.