Rollerblind Powered Troubleshooting
13
Spot cleaning
➤ Spot-clean with a soft white cloth, moistened with warm water. Add a mild deter-
gent if needed (non-abrasive and with no additives).
➤ Blot gently to avoid creasing or damaging the fabric. Always leave the blind
deployed to dry thoroughly.
Cleaning windows
➤ Always ensure the blinds are fully stowed before cleaning windows. This will
prevent spoiling the blind fabric by splatter or sprays of water or detergent.
10 Troubleshooting
Fault Solution
Guide wire tension too low ➤ See chapter “Fitting the guide wire ver-
sions” on page 10.
Guide wire too short ➤ Order replacement guide wire, see
spares leaflet at dometic.com.
Guide wire broken ➤ Order replacement guide wire, see
spares leaflet at dometic.com.
Motor not working ➤ Check if wiring for voltage to the motor is
correct.
➤ If power supply is checked and the motor
is still faulty contact your distributor.
➤ If using the AP Remote control refer to the
AP Remote control manual.
Guide wire or side track blind not running
smoothly
➤ Check restraint positions and recess
dimensions.
Side track not vertical ➤ Check if the side tracks are fitted perpen-
dicular to the roller and parallel to each
other.
Fabric rolls off sides of ends of roller ➤ Check if the guide wires or side tracks are
perpendicular to the roller and that the
roller is horizontal.
Blind stops in wrong position ➤ Refer to manual of your control device
(e.g. AP Remote control).
RollerblindPowered_IOM_EMEA16.book Seite 13 Donnerstag, 21. November 2019 9:37 09