EasyManuals Logo
Home>DSC>Security System>PowerSeries SCW9047

DSC PowerSeries SCW9047 User Manual

DSC PowerSeries SCW9047
64 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #60 background imageLoading...
Page #60 background image
Self Contained Wireless Alarm System v1.0
56
Appendix D: SIA False Alarm Reduction
SIA Feature
Programming Section
Comments Range/Default Require-
ment
Exit Time
[005], 3rd entry
Access to Entry and Exit delays and Bell Time Out for the system
Range:
45- 255 seconds
Default:
60 sec.
Required
(programmable)
Progress Annunciation/
Disable - for Silent Exit
[014], Option 6 ON
Enables audible exit beeps from the keypad for the duration of exit delay Keypads may be disabled
Default:
Enabled
Allowed
Exit Time Restart
[014], Option 2 ON
Enables the exit delay restart feature
Default:
Enabled Required
Auto Stay Arm on
Unvacated Premises
[001]-[002] Zone type 05, 06
Function Key: Stay Arming. All Stay/Away type zones (05, 06) will be automatically
bypassed
If no exit after full arm
Default:
Enabled
Required
Exit Time and Progress
Annunciation/Disable
or Remote Arming
[005] and [014] bit 6
System Times and Audible Exit beeps can be disabled when using the Key fob to arm
away the system
Default:
Enabled Allowed
Entry delay(s)
[005], 1st and 2nd entry
Access to Entry and Exit delays and Bell Time Out for the system
Note:
Combined Entry delay and Communications Delay (Abort Window) shall not
exceed 60s
Range:
30 sec. to 4 min.
Default:
30 sees
Required
(programmable)
Abort Window
for Non-Fire zones
[101]-[134] bit 6 ON
Access to zone attributes, i.e, swinger shutdown, transmission delay and cross zone.
Individual zones attribute bit 6 (Transmission delay) is by default ON
May be disabled
by zone or zone type
Default:
Enabled
Required
Abort Window - for
Non-Fire zones
[377], 4th entry
Access to the programmable delay before communicating alarms
Note:
Combined Entry delay and Communications Delay (Abort Window) shall not
exceed 60s
Range:
15 - 45 sec.
Default:
30 sees
Required
(programmable)
Abort Annunciation
[382], Option 3 ON
Enables the “Communication Cancelled” message display on keypad Annunciate that no
alarm was transmitted
Default:
Enabled
Required
Cancel Annunciation
[328], 8th entry
Access to the reporting code for Alarm Cancelled Annunciate that a
Cancel was transmitted
Default:
Enabled
Required
Duress Feature
[*][5] Master Code
Option 2 ON
Do not derive code from an existing Master/User code (e.g., Master code is 1234, the
duress code should not be 1233 or 1235)
No 1+/- derivative of another
user code. No duplicates with
other user codes
Default:
disabled
Allowed
Cross Zoning
[016] Option 1
[101]-[134] bit 8 OFF
This option enables Cross Zoning for entire system. Individual zones can be enabled
for Cross zoning via Zone attribute bit 8 in sections [101] - [134]
Programming required
Default:
Disabled
Required
Cross Zone Timer
[176]
Access to the programmable Cross Zone timer May program
Range: 001-255 sec./min.
Default:
60 secs
Allowed
Swinger Shutdown for Alarms
[377] 1st entry
Access to the swinger shutdown limit for zone alarms For all non-fire zones
shut down at 1 or 2 trips
Default:
1 Trip
Required
(programmable)
Swinger Shutdown Enable
[101] - [134] bit 6 ON
Access to zone attributes, i.e., swinger shutdown, transmission delay and cross zone.
Individual zones attribute bit 6 (Swinger shutdown enabled) is by default ON
For non-police
response zones
Default:
Enabled
Allowed
24-Hr. Auto_verified Fire
(Wireless) Zone type [89]
Access to 24-Hr. Auto_verified Fire (Wireless) Activates If a restoral is Not
received within the specified
time
Default:
disabled
Required
Call Waiting Cancel Dial String
[304], [382], Option 4 OFF
Access to the dialing sequence used to disable call waiting Dependant on user phone
line
Default:
disabled
Required
Testing
System Test:
[*][6] Master Code, Option 4
The system activates all keypad sounders, bells or sirens for 2 seconds and all keypad lights turn on.
Refer to the User Manual (part no. 29007326).
Walk Test Mode:
[*][6] Opt 8
This mode is used to test each zone on the system for proper functionality.
Alarm Communications
During Walk Test
[382] Option 2:
Enables Communication of zone alarms while Walk Test is active.
Walk Test End and Begin
Reporting Codes
[348], 1
st
and 2
nd
Entries
Access to the reporting codes for Walk Test Begin and Walk Test End.
WWW.DIYALARMFORUM.COM

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the DSC PowerSeries SCW9047 and is the answer not in the manual?

DSC PowerSeries SCW9047 Specifications

General IconGeneral
BrandDSC
ModelPowerSeries SCW9047
CategorySecurity System
LanguageEnglish

Related product manuals