Power 832 Application Notes – X-10 Automation (Schedule Control)
Application: The ESCORT can be used to control up to 32 X-10 automation devices. This Application
Note will cover the basic programming required for scheduling light control, specifically
to turn a light on at 8:00 am and off at 8:00 pm, every day of the week. Additional
Application Notes are available for output and manual control.
Equipment:
- Power 832 control panel
- ESCORT 5580 module
- X-10 controller (PL-513 or PSC-04)
- X-10 light module
Special Notes:
Program Sections: ESCORT Section [002] - First System Options
ESCORT Section [007] - Number of Automation Transmissions
ESCORT Section [130] - Item #01 House Code & Unit Number
ESCORT Section [131] - Item #01 Miscellaneous Options
ESCORT Section [132] - Item #01 Schedule Assignment
ESCORT Section [134] - Item #01 Schedule/Output Condition
ESCORT Section [030] to [032] - Schedule #01 Programming
Procedure:
To enter ESCORT programming, perform the following on any local touch tone phone:
- Enter [*] [*] [*] on any local touch tone phone to turn the ESCORT on
- Enter [*] [8] [ESCORT Service Code] – default is [5580]
For information regarding how the ESCORT is programmed, please refer to the ESCORT 5580 Installation
Manual.
Step 1 – First System Options – ESCORT Section [002]
• Turn Option [03] ON to enable Home Automation.
• An access can be required to enter the [*] [5] Automation for additional security. If Option [04] is ON,
an access code is required. If Option [04] is OFF, an access code is not required.
Step 2 – Number of Automation Transmissions – ESCORT Section [007]
The number of Automation transmissions can be changed to increase reliability. Since the Automation
transmissions are non-confirmed and occur over the existing AC wiring of the premises, having the
ESCORT transmit multiple On/Off commands can increase reliability.
• Program the number of on/off transmissions to be sent for each command.
• Note, each transmission takes approximately one second. The larger the number, the slower the
Automation system will appear to operate.