Escort5580TC and EMS-100 - Thermostat Scheduling Control
Application: Typical home installation with one thermostat. This application will provide an example
for setting the temperature by schedule. The Escort will automatically change the
temperature to the programmed setting at 8:00 am and 11:00 pm.
Equipment:
- Power 832 v2.x or greater
- LCD5500 v2.1 or greater (optional)
- Escort5580TC Module
- EMS-100 Thermostat
- EMS-ITS Internal Temperature Sensor (optional)
- EMS-OTS Outdoor Temperature Sensor (optional)
Special Notes:
1. The Application Note assumes that the EMS-100 will be used to control both heating and cooling.
2. The user cannot ‘temporarily’ change the temperature. Any time the user manually changes the
temperature set point for an Occupancy Setting, it will change to the new setting.
Program Sections: Escort Section [030] to [032] - Schedule [01] Programming
Escort Section [033] to [035] - Schedule [02] Programming
Escort Section [800] - Thermostat 1 Options
Escort Section [801] - Thermostat 1 Day Setting Schedules
Escort Section [803] - Thermostat 1 Day Setting Output Option
Escort Section [806] - Thermostat 1 Night Setting Schedules
Escort Section [808] - Thermostat 1 Night Setting Output Option
Procedure:
For information regarding how the Escort is programmed, please refer to the Escort5580TC Installation
Manual.
Step 1 – Schedule [01] Programming – Escort Section [030] to [032]
Each of the 16 schedules contain three program items; On time, Off Time and Day of the Week selection.
The new temperature will be set when the schedule is activated (On Time) so no Off Time is required.
Schedule [01] will be used for the Day Occupancy Setting (starting at 8:00 am) and will be programmed as
follows:
Program data [0800] in Section [030] (8:00 am On Time)
Program data [9999] in Section [031] (no Off Time is required)
Turn Options [01] through [07] ON in Section [032] to enable all days of the week.

Other manuals for DSC PowerSeries

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the DSC PowerSeries and is the answer not in the manual?

DSC PowerSeries Specifications

General IconGeneral
BrandDSC
ModelPowerSeries
CategorySecurity System
LanguageEnglish

Related product manuals