6
2. INSTALLING PROCEDURE
2-4. Checking the Suction Collator EPROM
Check the version of the EPROM in the ROM number check mode of the suction collator.
(1) Press the numerical keys on the control panel in the following order. 1 2 3 4 5 6
(2) Press the STOP key. The ROM number will be displayed on the display window as follows.
For the DC-10000S
“A-?” Display the ROM number of Tower A.
Press the STOP key.
“b-?” Display the ROM number of Tower B.
Press the STOP key.
“C-?” Display the ROM number of Tower C.
Press the STOP key.
“d-?” Display the ROM number of Tower D.
Press the STOP key.
“E-?” Display the ROM number of Tower E.
Press the STOP key.
“F-?” Display the ROM number of Tower F.
Release the check mode using the STOP key.
For DC-6000S, up to “C-?” will be displayed. For DC-8000S 2, up to “d-?” will be displayed.
DC-6000S If the version is 99L-80212 or more, it need not be replaced.
DC-8000S 2 If the version is 96F-82498 or more, it need not be replaced.
DC-10000S If the version is 96F-81999 or more, it need not be replaced.
NOTE : The DBM-120 will not operate normally with EPROMs of versions below the versions indicated above.
Use the same EPROM versions for all towers connected.
The EPROM is a service parts.
1

Other manuals for Duplo DBM-120

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Duplo DBM-120 and is the answer not in the manual?

Duplo DBM-120 Specifications

General IconGeneral
BrandDuplo
ModelDBM-120
CategoryFolding Machines
LanguageEnglish

Related product manuals