Line Inspection
Line Inspection
Line Inspection and Road Test Instructions
Refer to the Line Inspection Form while performing the following procedure:
1. Power Supply Checks:
DDEC - Visually verify the power connections at the battery bus through a 10 amp circuit breaker or fuse.
Caterpillar - Visually verify the ground connection between the solenoids and truck.
Cummins - Visually verify the ground connection between the solenoids and truck.
2. Oil Fill:
Verify the transmission has been filled with the correct amount of oil and type before starting engine. Failure to add
sufficient oil could damage the transmission. Use Eaton Roadranger CD50 or equivalent as specified in TCMT-0021
the Roadranger Product Lubrication Manual on the www.Roadranger.com Literature Center.
3. End-of-line Programming
See page 19, page 21, page 29, or page 31 depending on your engine type.
Dyno / Road Test
4. Verify correct clutch adjustment and correct pedal free travel per clutch manufacturer’s requirements.
5. Verify through normal operation that all transmission forward and reverse gears can be obtained. Verify transmission
makes automatic shifts in lever position “AUTO”.
6. Visually check for oil drips or residue on the transmission and related cooler lines, if used.
7. Make sure that the correct transmission dash label is present and that the drivers instruction booklet is included with
the other vehicle information.
8. Verify that a label to alert the customer of type and brand of oil used in the transmission is attached tot the transmission
or included with other vehicle information.
9. Clear fault codes in the engine ECM. Refer to OEM engine literature.