EasyManuals Logo
Home>Eaton>Microphone system>Fuller RTLO-16610B

Eaton Fuller RTLO-16610B User Manual

Eaton Fuller RTLO-16610B
40 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #14 background imageLoading...
Page #14 background image
11
Installation Requirements
9-speed Pneumatic Diagrams
Note: Only solid lines are connected by the OEM. Dashed lines are already plumbed.
Roadranger
valve
HI Range Inactive
LO Range Pressured
HI Range Pressured
LO Range Inactive
5/32" or 1/8" air line
1/4" air hose
1/4" air hose
HI Range Inactive
LO Range Pressured
Range
Cylinder
1/4" air hose
Constant regulated
air (55-65 PSI)
Air filter/
regulator
Constant regulated
air (55-65 PSI)
1/4" air hose
Splitter
Cylinder
5/32" air line
Lock High
Except During
Top 2 Function
Top 2
Solenoid
Valve
HI Split Pressured
LO Split Inactive
5/32" air line
5/32" air line
Constant regulated
air (55-65 PSI)
5/32" or 1/8" air line
Slave
Valve
H
L
S
P
S
L
P1
P2
S
EXH