7 Command format
In sleep modeMode 3M1=off, M0=off, it supports below instructions on list.
(Only support 9600 and 8N1 format when setting)
No.
Instruction
format
Illustration
1
C0+working
parameters
C0 + 5 bytes working parameters are sent in hexadecimal format. 6 bytes in total and
must be sent in succession, ( Save the parameters when power-down ).
2
C1+C1+C1
Hexadecimal format sends three C1, the module returns saved parameters, must be sent
continuously.
3
C2+working
parameters
Send C2+5 bytes in hexadecimal format: 6 bytes of working parameters, must be sent
continuously (power off without saving)
4
C3+C3+C3
Hexadecimal format sent three C3, the module return version information, must be sent
continuously.
5
C4+C4+C4
Hexadecimal format sent three C4, the module will produce a reset, must be sent
continuously.
7.1 Default parameters
Type
Default parameter valuesC0 00 00 1C 20 64
Model
The
network
number
Slave
address
Air data rate
Baud rate
Parity
Transmitting
Power
FEC
E64-DTU (433NW20)
0x00
0x00
8kbps
9600
8N1
100mW
on
7.2 Reading operating parameters
Instruction format
Description
C1+C1+C1
In sleep modeM0=1M1=1),
User gives the module instruction (HEX format): C1 C1 C1,
Module returns the present configuration parameters.
For example, C0 00 00 1C 20 64.