Chengdu Ebyte Electronic Technology Co., Ltd. NE2-D11/NE2-D12 User Manual
Copyright © 2012-2024, Chengdu Ebyte Electronic Technology Co., Ltd.
25
4.4 Advanced parameter
4.4.1 Link protocol distribution
supports socket distribution protocol, which can send data to different links through specific
protocols, and can also distinguish the data received by different links by adding headers and trails.
Upper computer software configuration steps:
After turns on the multi-link protocol distribution mode, there are the following possibilities.
Here, for example,link 1connects to server port 8887, and link 2connects to server port 8888:
1. The data sent by serial port meets the data header of 55 FE AA 00, that is, meets the
requirements, that is, 55 FE AA 00 + data, then the data will only be transmitted to Socket 1,
and the received content only contains data, not data header;