Chengdu Ebyte Electronic Technology Co., Ltd. NE2-D11/NE2-D12 User Manual
Copyright © 2012-2024, Chengdu Ebyte Electronic Technology Co., Ltd.
6
Default local port
Subnet mask
Default gateway
Default working mode
Serial port baud rate
Serial port parameters
2.3.3 Data transmission test
After the above operation steps, the transparent transmission test of data can be realized by
following the factory default parameters of the equipment and performing the following operations.
The operation steps are as follows:
1
Open the Test TCP/IP Debugging Assistant software.
2 In the "Network Settings" area, select TCP Client mode, the remote host address
corresponds (the default local IP of the device is 192.168. 3.7), and the remote host port corresponds
to the factory local port 8886 of the device, and click Connect.
3 Wait for the computer to connect to the serial server, and the LINK lamp of the serial
server will always be on after the connection is completed.
4
Open the serial port assistant, set the baud rate of the serial port to 115200, and set the
serial port parameters to 1/8/None. Click to open the serial port.