Retro- Kit Installation Only (Apex to Apex2)
Rinse Aid Dispenser Out of Product Signal
1. Open the front cover of the rinse dispenser by removing the stainless
steel hinge pin
2. Within the wire harness locate the white-to-white connection and
disconnect
Note: Disconnecting the white-to-yellow connection will cause the dispenser to
function incorrectly and not fill reservoir.
3. Connect the supplied grey wire to the male connector of the white wire
4. Route the grey wire out the bottom of the rinse dispenser to the Apex2
I/O Enclosure
Note: Leave the remaining white terminal connector unconnected.
5. Replace the front cover
Removing Apex Board
1. Open existing Apex controller and disconnect:
a. Probe Cable [A]
b. Phoenix Connectors [B, C, and D]
i. Pressure Switch wire leads may require loosening terminal screw
c. Rinse Motor and Detergent Valve Connectors [E]
(Do not cut wires at this time)
d. Power Supply [F]
A
B
C
D
E
F
Figure 4.16
Figure 4.14
Figure 4.15