4.4.3 Rinsing mode
By calling up the "Rinsing mode" function
Ä
Chapter 4.4.1 ‘Beverage mode’
on page 21, Fig. 6, pos. 4, the display message changes and rinsing can be started.
Fig. 19: Rinsing mode - schema 1
The "Rinsing mode" is activated by pressing [OK].
Fig. 20: Rinsing mode - schema 2
Before rinsing starts, the remaining cleaning liquid is removed from the mixing container.
If the mixing container is empty
, the water valve opens and the mixing container is refilled.
Fig. 21: Rinsing mode - schema 3
If the upper filling level is reached, the rinsing will be started with water.
Fig. 22: Rinsing mode - schema 4
If the level is below the mid filling level, the water valve opens and the mixing
container is filled.
If the middle filling level will be underrun, a counter will be activated. If the middle filling
level not be underun after
5 seconds, the rinsing will be stopped and the mixing container
refilled again. In this case, the water valve will be opened at underrun of the upper filling
level.
Control / Visualisation
26Rev. 04-06.2018

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Ecolab DM Modular 20 and is the answer not in the manual?

Ecolab DM Modular 20 Specifications

General IconGeneral
BrandEcolab
ModelDM Modular 20
CategoryCleaning Equipment
LanguageEnglish

Related product manuals