RINSE SPEED CONTROL P.C. BOARD
6.4 Sonalert
®
Volume Adjustment
1. Turn all alarm delay switches off.
2. Put the unit into a feed mode by temporarily turning on
additional titration switches and disrupting detergent feed
by holding open the Geosystem Detergent Dispenser
lid.
3. When the Sonalert
®
is activated, set the volume using

volume, refer to Figure 6-1.
The Sonalert
®
volume should be loud enough to be heard
over the normal noise levels in the dish room , and yet not
too loud that it may disturb customers in the dining room.
6.5 Sonalert
®
Alarm Delay
1. Set the alarm delay by using the 10 position dip switch,
refer to Figure 6-1.
          
          


NOTE: On Door Type Machines, the delay should be
approximately 30-35 seconds to allow it to be activated
before the wash cycle is complete.
NOTE: On Conveyer Machines, (unless equipped with
a D-ENERGIZER or other time-out device) the delay
should be a minimum of 2 minutes.
6.6 Rinse Speed Control
This is the normal mode of operation as a dishmachine
rinse injector. Thru the pressure switch, the pump is ac-
      
speed control, the injection rate of the rinse additive can be
controlled throughout the entire rinse cycle, refer to Figure
6-2. Injection rate can also be adjusted by use of alternate

INJECTION RATES
PUMP SPEED
Tube Size 3 RPM (minimum) 36 RP M ( m ax i-
mum)
  
  
  
  
  
  
* Tubing provided with GeoCenter unit.
NOTE: 1cc = 1 ml
Figure 6-2

POTENTIOMETERS
PUMP SPEED
POTENTIOMETER
NOTE: The best injection rates are achieved in the 10-20
revolution per minute range. It is recommended to select
the tubing that allows mid range operation.
6.7 Timed Feed
In this mode of operation, the dispenser will activate for a
pre-set period of time. This would be used when dispensing
control is determined by volume, refer to Figure 6-2.
Note that the TIME FEED and the SPEED CONTROL
modes can be used together. For example, if the injector

setting the TIME FEED for just a few seconds longer than
the normal rinse time, this will be the maximum length of

6.8 Feed Delay
This feature can be used with either the SPEED CONTROL
or TIME FEED mode. This is adjustable from 0 to 10 seconds,
and delays the pump activation for that period of time after
the unit is activated, refer to Figure 6-2.