36 ECTIVE BB & SBB
Charging Process
Boost Charge
Charges according to the maximum current until the battery voltage
reaches the constant voltage charging voltage.
Constant Voltage Charge
When the battery voltage has risen to the appropriate level, the current
begins to fall and the constant voltage charge mode is begun. The
constant voltage charging time is 2h. When the battery voltage is above
12.6V, the constant voltage charging is endend and the floating charge is
directly charged
Float Charge
After the constant voltage charge is completed, the float charge begins
and maintans the battery charge without overchargig.
Protective Features
Main Battery Over-Voltage
If battery voltage is above the HVD: charging is interrupted.
If battery voltage is greater than boost charge voltage +0.2V for 10
continuous seconds, charging is interrupted.
A buzzer alarm will sound for one minute (— — —).
Main Battery Low-Voltage Protection
If the battery voltage is below LVD, a buzzer alarm will sound for one
minute (-- -- --).