EasyManuals Logo
Home>EINHELL NEW GENERATION>Inverter>STE 5000D

EINHELL NEW GENERATION STE 5000D User Manual

EINHELL NEW GENERATION STE 5000D
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #17 background imageLoading...
Page #17 background image
17
GB
Fault Cause Remedy
Engine does not start - Oil pressure switch tripped (red LED
(Fig. 2/Item 17))
- No diesel fuel
- Mechanical switch (Fig. 6/Item A)
set to “STOP”
- Diesel filter blocked
- Air filter dirty
- Diesel filter frozen due to low out
door temperature
- Check oil level, top up with engine
oil
- Top up with diesel fuel
- Set mechanical switch to “RUN”
- Clean or replace the diesel filter
- Clean or replace the air filter
- Proceed as described in the point
entitled “Winter operation”
Generator has too little or no
voltage
- Controller or capacitor defective
- Overcurrent circuit-breaker has
tripped
- Carbon brushes in generator worn
- Contact authorized after-sales
service outlet
- Press the switch and reduce the
consumers
- Contact authorized after-sales
service outlet
12. Troubleshooting