24
© 2016 Emerson Climate Technologies, Inc.
AE4-1303 R15
Field Service
WARNING
Remove refrigerant charge from both the low
and high side of the compressor before cutting
the suction and discharge lines to remove
the compressor. Verify the charge has been
completely removed with manifold gauges.
• To disconnect: Reclaim refrigerant from both the
high and low side of the system. Cut tubing near
compressor.
• To reconnect:
○ Recommended brazing materials: Silfos
with minimum 5% silver or silver braze
materialwithux.
○ Inserttubingstubsintottingandconnect
to the system with tubing connectors.
○ Follow New Installation brazing
New Installations
• The copper-coated steel suction tube on scroll
compressors can be brazed in approximately the
same manner as any copper tube.
• Recommended brazing materials: Any silfos
material is recommended, preferably with a
minimum of 5% silver. However, 0% silver is
acceptable.
• BesuresuctiontubettingI.D.andsuctiontube
O.D.are cleanprior toassembly. Ifoil lmis
present wipe with denatured alcohol, Dichloro-
Triuoroethaneorothersuitablesolvent.
• Using a double-tipped torch apply heat in Area 1.
As tube approaches brazing temperature, move
torchametoArea2.
• Heat Area 2 until braze temperature is attained,
moving torch up and down and rotating around
tube as necessary to heat tube evenly. Add
braze material to the joint while moving torch
around joint to ow braze material around
circumference.
• After braze material ows around joint, move
torch to heat Area 3. This will draw the braze
material down into the joint. The time spent
heating Area 3 should be minimal.
• As with any brazed joint, overheating may be
detrimentaltothenalresult.
}
}
}
1
2
3
Figure 6
Scroll Suction Tube Brazing