FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY
BEFORE INSTALLING OR OPERATING THIS CONTROL COULD CAUSE
PERSONAL INJURY AND/OR PROPERTY DAMAGE.
The 36H series combination gas valve has redundant
and main solenoid valves that control gas ow to the
main burners, a pressure regulator to maintain a con-
stant outlet pressure, and a two position on/o switch
for electrical shuto. The valves are shipped from the
factory set for natural gas non-piloted applications.
See instructions in this document for modications
required if the valve is to be installed on an LP gas
and/or piloted gas application.
36H SERIES
Combination Gas Valve
INSTALLATION INSTRUCTIONS
CONTENTS
Description ..................................................... 1
Specications ................................................. 1
Precautions ..................................................... 3
Installation ...................................................... 4
System Wiring
Adjustment ..................................................... 7
Pressure Regulator Adjustment
Lighting Instructions ........................................ 8
T
ype of Gas: ...................... Natural Gas
Ambient Temperature: .... -40° to 175°F
Pressure Rating: ............... 14” W.C. (1⁄2 PSI) max.
Voltage: ............................ 24 VAC
Frequency: ....................... 50/60 Hz
Current: ............................ Single Stage - .410A
Two-Stage - .540A
Model
No.
No. of
Stages
Open
Characteristics
Proven/
Intermittent
Pilot
HSI DSI
36H32 1
Fast Yes Yes Yes
36H33 1
Slow Yes Yes Yes
36H64 2
Fast Yes Yes Yes
36H65 2
Slow Yes Yes Yes
Pressure Regulator Adjustment Range ( in W.C.)
Single
Stage
Two Stage
Low High
Min Di.
Low to High
Natural Gas
2.5 - 5.0 1.0 - 3.5 2.5 - 5.0 1.5
LP Gas
5.0 - 12.0 4.0 - 9.5 8.0 - 12.0 2.5
PIPE SIZES/CAPACITIES
Pipe Sizes
Available (inches)
Capacity (BTU/hr) at 1” W.C.
pressure drop across valve
AGA Std. Nat. Gas
(1,000 btu/ cu. ft.)
LP. Gas
(2,500 btu/cu. ft.)
3/4” x 3/4” NPT 300,000 486,000
1/2” x 3/4” NPT 260,000 421,000
SPECIFICATIONS
DESCRIPTION
PART NO. 37-7336B
Replaces 37-7336A
1429
avrora-arm.ru
+7 (495) 956-62-18

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Emerson White Rodgers 36H Series and is the answer not in the manual?

Emerson White Rodgers 36H Series Specifications

General IconGeneral
BrandEmerson
ModelWhite Rodgers 36H Series
CategoryControl Unit
LanguageEnglish

Related product manuals