-- 1 2 --
ba41d1ea
8 FAULT--TRACING
Try these recommended checks and inspections before sending for an authorized
service technician.
Type of fault Corrective action
No arc S Check that the mains power supply switch is
turned on.
S Check that the welding and return cables
are correctly connected.
S Check that the correct current value is set.
S Check the mains power supply fuses.
The welding current is interrupted during welding. S Check whether the overloading protection
has tripped (indicated in the control panel).
S Check the mains power supply fuses.
The overloading protection trips frequently. S Check to see whether the dust filter is
clogged.
S Make sure that you are not exceeding the
rated data for the power source (i.e. that the
unit is not being overloaded).
Poor welding performance S Check that the welding and return cables
are correctly connected.
S Check that the correct current value is set.
S Check that the correct wire or electrode is
used.
S Check the mains power supply fuses.
9 ORDERING SPARE PARTS
Repair and electrical work should be performed by an authorized ESAB serviceman.
Use only ESAB original spare and wear parts.
Mig 3001i is designed and tested in accordance with the international and European
standards EN 60974--1 and EN 60974--10. It is the obligation of the service unit which
has carried out the service or repair work to make sure that the product still conforms
to the said standard.
Spare parts may be ordered through your nearest ESAB dealer, see the last page of
this publication.
GB