28
* All images are for indication only; please refer to your individual unit for actual item.
Injector Size Table
Burner Injector Values According To The Gas Type.
Destination: GB Gas Category II
2H3+
LPG Natural Gas
G 30/31
28-30/37 mBar
G 20
20 mBar
Large Burner (Fast)
Injector mm 0.83 1.17
Gas Flow (15°C and 1013mbar) 203 gr/h 266 lt/h
Power kW 2.800 2.800
Standard Burner
Injector mm 0.67 0.98
Gas Flow (15°C and 1013mbar) 131 gr/h 171 lt/h
Power kW 1.800 1.800
Small Burner (Simmer)
Injector mm 0.52 0.72
Gas Flow (15°C and 1013mbar) 73 gr/h 95 lt/h
Power kW 1.000 1.000
Main Oven Burner
Injector mm 0.79 1.15
Gas Flow (15°C and 1013mbar) 183 gr/h 238 lt/h
Power kW 2.500 2.500
• All intervention regarding installation maintenance and conversion of the appliance must be fullled with
original factory parts.
• The manufacturer declines any liability if these correct parts are not used.
Where to place the LPG Replacement Rating Plate Sticker
If the oven is changed to LPG, the replacement rating plate sticker MUST be placed as shown below.
5 017416 768337
5010GG5.33ZPFGW cf
CFSGWH17