1.7 VENTILATION & RACK MOUNTING
Adequate ventilation is obviously required for optimum performance. As a result of
this consideration, ensure no other equipment is located close to the mainframe.
Important
• Remember that fans are used to air cool the equipment and protect it
from overheating.
• Do not block fans intakes during operations.
Having regard to the weight of the XT3 chassis, support guides are required for
this unit into the rack mount. The front ears of the XT3 unit are not designed to
support its full weight. Applying full weight on these might result in bending the
metal plate.
1.8 XT3 SERVER MAIN SPECIFICATIONS
1.8.1 ELECTRIC SPECIFICATIONS
The following electrical specifications are valid for the XT3 6U server:
Data Type Voltage Values
Inrush current
(PSU plugged on power grid)
230 V 3.8 A
Maximal current
(full load, CPU at 100% )
230 V 1.7 A
Inrush current
(PSU plugged on power grid)
110 V 7.9 A
Maximal current
(full load, CPU at 100% )
110 V 3.6 A
Maximal power consumption
(full load, CPU at 100%)
- 400 W