Introduction
Congratulations on your purchase of this Extech Meter. The PRT200 is used to quickly and
accurately determine three phase sequence for motor installation and repair. The non-contact
voltage detecting technique permits easy connection to insulated conductors, avoiding uncertain
and difficult connections to bare high voltage wires. This meter is shipped fully tested and
calibrated and, with proper use, will provide years of reliable service.
Safety
International Safety Symbols
This symbol, adjacent to another symbol or terminal, indicates the user must refer to the
manual for further information.
This symbol, adjacent to a terminal, indicates that, under normal use, hazardous voltages
may be present.
Double insulation
Safety Notes
1. Read the following safety information carefully before attempting to operate the tester.
2. Use the tester only as specified in this manual or the protection provided by the tester may
be impaired.
3. This instrument cannot identify a missing earth line.
4. To assure accurate results, do not touch the clips during measurements.
5. Do not pull the cable when removing the measurement clips from the measured conductors.
It may damage the test lead.
6. Do not expose the instrument to direct sunlight, high temperature, high humidity or dew.
7. Keep the tester dry! Do not use the instrument when it is wet.
8. Do not mix old batteries with new ones.
9. Never open the battery compartment cover while connected to live conductors.
10. Avoid large shocks or vibrations, they may damage the tester.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Extech Instruments PRT200 and is the answer not in the manual?

Extech Instruments PRT200 Specifications

Power IconPower
input voltage75 to 1000VAC
batteries4 x 1.5V AA
current consumption15mA
Operating Environment IconOperating Environment
operating temperature & humidity-10°C to 50°C (14°F to 122°F) Max. 80% R.H.
storage temperature & humidity-20°C to 60° (-4°F to 140°F) Max. 80% R.H.
frequency range45 to 65Hz
Weight and Dimensions IconWeight and Dimensions
max conductor diameter33 mm (1.3”)
probe length86 cm (34”)