Maintenance
Battery Replacement
When the ON LED begins to flash, the batteries need to be replaced.
1. Remove the clips from any conductors.
2. Remove the screw holding the battery compartment cover and remove the cover.
3. Replace the four AA batteries.
4. Replace the battery cover.
You, as the end user, are legally bound (Battery ordinance) to return all used batteries
and accumulators; disposal in the household garbage is prohibited!
You can hand over your used batteries / accumulators at collection points in your
community or wherever batteries / accumulators are sold!
Disposal: Follow the valid legal stipulations in respect of the disposal of the device at the
end of its lifecycle.
Cleaning and storage
Periodically wipe the case with a damp cloth. Do not use abrasives or solvents.
A small standby current flows when the meter is off. If the meter is not to be used for a period longer
than 60 days, remove the batteries and store them separately.
Specifications
Measurement Principle Static induction
Input Voltage 75 to 1000VAC
Frequency Range 45 to 65Hz
Max conductor diameter 33mm (1.3”)
Probe length 86cm (34”)
Auto-Off 5 min. without sequence detection
Low Battery Warning Power LED flashes
Batteries 4 x 1.5V AA
Current consumption 15mA
Operating Temperature & Humidity -10°C to 50°C (14°F to 122°F) Max. 80% R.H.
Storage temperature & Humidity -20°C to 60° (-4°F to 140°F) Max. 80% R.H.
Safety This meter is intended for origin of installation use and
protected, against the users, by double insulation per
EN61010-1 to Category IV 600V and Category III 1000V;
Pollution Degree 2.
Approvals CE
Copyright © 2011 Extech Instruments Corporation (a FLIR company)
All rights reserved including the right of reproduction in whole or in part in any form.
Test Equipment Depot - 800.517.8431 - 99 Washington Street Melrose, MA 02176 - TestEquipmentDepot.com

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Extech Instruments PRT200 and is the answer not in the manual?

Extech Instruments PRT200 Specifications

Power IconPower
input voltage75 to 1000VAC
batteries4 x 1.5V AA
current consumption15mA
Operating Environment IconOperating Environment
operating temperature & humidity-10°C to 50°C (14°F to 122°F) Max. 80% R.H.
storage temperature & humidity-20°C to 60° (-4°F to 140°F) Max. 80% R.H.
frequency range45 to 65Hz
Weight and Dimensions IconWeight and Dimensions
max conductor diameter33 mm (1.3”)
probe length86 cm (34”)