FOR INSTALLERS AND
PROFESSIONALS
NO. DISPLAY
1 E3
No water protection
2 E5
Power supply excesses operation range
3 E6
Excessive temp difference between inlet and outlet water(Insufficient water flow
protection)
4 Eb
Ambient temperature
5 Ed Anti-
freezing reminder
NO. DISPLAY
1 E1
High pressure protection
2 E2
Low pressure protection
3 E4
3 phase sequence protection (three phase only)
4 E7
Water outlet temp too high or too low
5 E8
High exhaust temp protection
6 EA
Evaporator overhe
7 P0
Controller communication failure
8 P1
Water inlet temp sensor failure
9 P2
Water outlet temp sensor failure
10 P3
Gas exhaust temp sensor
11 P4
Evaporator coil pipe temp sensor failure
12 P5
Gas return temp sensor failure
13 P6
Cooling coil pipe temp sensor failure
14 P7
Ambient temp sensor failure
15 P8
Cooling plate sensor failure
16 P9
Current sensor failure
17 PA Restart
memory failure
18 F1
Compressor drive module failure
19 F2
PFC module failure
20 F3
Compressor start failure
21 F4
Compressor running failure
22 F5
Inverter board over current protection
23 F6
Inverter board overheat protection
24 F7 Current
protection
25 F8
Cooling plate overheat protection
26 F9
Fan motor failure
27 Fb
Power filter plate No
28 FA
PFC module over current protection
16
PROFESSIONALS
4. FAILURE CODE
NOT FAILUREDESCRIPTION
No water protection
Power supply excesses operation range
Excessive temp difference between inlet and outlet water(Insufficient water flow
Ambient temperature
too high or too low protection
freezing reminder
FAILUREDESCRIPTION
High pressure protection
Low pressure protection
3 phase sequence protection (three phase only)
Water outlet temp too high or too low
protection
High exhaust temp protection
Evaporator overhe
at protection (only at cooling mode)
Controller communication failure
Water inlet temp sensor failure
Water outlet temp sensor failure
Gas exhaust temp sensor
failure
Evaporator coil pipe temp sensor failure
Gas return temp sensor failure
Cooling coil pipe temp sensor failure
Ambient temp sensor failure
Cooling plate sensor failure
Current sensor failure
memory failure
Compressor drive module failure
PFC module failure
Compressor start failure
Compressor running failure
Inverter board over current protection
Inverter board overheat protection
protection
Cooling plate overheat protection
Fan motor failure
Power filter plate No
-power protection
PFC module over current protection
Excessive temp difference between inlet and outlet water(Insufficient water flow

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fairland TurboSilence InverX IXCR26 and is the answer not in the manual?

Fairland TurboSilence InverX IXCR26 Specifications

General IconGeneral
BrandFairland
ModelTurboSilence InverX IXCR26
CategoryHeat Pump
LanguageEnglish

Related product manuals