08-4
To remove water:
• The water will be mixed to the desired
temperature according to the position of the
pre-mixing unit.
Emptying the therme:
• Switch off the electricity for the water pump
by pressing the control panel
l
of the main
switch for 5 seconds.
• Open all faucets.
• Set all pre-mixing valves to "warm" if neces-
sary.
• Open the drain valves
m
.
4 directly next to the therme; another 2 on the
opposite side (layout/model-specic).
• Check to see if water runs out.
• Close the runoff valve
m
after emptying (if
necessary, blow the line out).
Electric operation:
• Use the switch
l
to turn on the therme. Use
the thermostat to regulate the water tempera-
ture to approx. 55° C.
• Power consumption: approx. 300 W.
Rules for the therme:
• Switch the device off when the camper is not
being used.
• Empty the therme at the risk of frost. Frozen
water can cause the therme to burst!
• A depressuriser must be used if the pump is
connected to a central water supply, or on
stronger pumps. The pressure in the therme
may not exceed 1.2 bar. In addition, a safety
valve or runoff valve
j
must be used in the
cold water tap.
• We recommend that you do not use the water
from the therme as drinking water.
Never operate the therme electrically
when it is empty.
WARNING:
The block circuit diagram only reects the func-
tion. Due to the various oor plans, individual
modications are possible.
Plan for warm water supply
2
1
3
4