EasyManuals Logo
Home>FLIR>Thermal cameras>E86

FLIR E86 User Manual

FLIR E86
134 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #117 background imageLoading...
Page #117 background image
Fetching data from external FLIR meters
22
22.4 Typical moisture measurement and
documentation procedure
The following procedure can form the basis for other procedures using FLIR meters and
infrared cameras.
1. Use the infrared camera to identify any potential damp areas behind walls and
ceilings.
2. Use the moisture meter to measure the moisture levels at various suspect locations
that may have been found.
3. When an area of particular interest is located, store the moisture reading in the mois-
ture meter’s memory and identify the measurement area with a handprint or other
thermal identifying marker.
4. Recall the reading from the meter memory. The moisture meter will now continuously
transmit this reading to the infrared camera.
5. Use the camera to take a thermal image of the area with the identifying marker. The
stored data from the moisture meter will also be saved on the image.
22.5 More information
For more information, see the user manuals that are shipped with FLIR meters.