Choice of location
Proper use The inverter is designed to be connected and used exclusively in conjunction with un-
grounded solar modules. The solar modules must not be grounded at either the positive or
negative pole.
The solar inverter is intended exclusively to convert direct current from solar modules into
alternating current and to feed this into the public grid.
Utilisation not in accordance with the intended purpose comprises:
- any use above and beyond this purpose
- making any modifications to the inverter that have not been expressly approved by
Fronius
- the installation of components that are not distributed or expressly approved by Froni-
us.
Fronius shall not be liable for any damage resulting from such action.
No warranty claims will be entertained.
Proper use also includes
- carefully reading and obeying all the instructions and all the safety and danger notices
in the operating instructions
- performing all stipulated inspection and maintenance work
- installation as specified in the operating instructions
When designing the photovoltaic system, ensure that all of its components are operated
within their permitted operating ranges at all times.
Observe all the measures recommended by the solar module manufacturer to ensure the
lasting maintenance of the properties of the solar module.
Obey the regulations of the power supply company regarding energy fed into the grid.
General com-
ments regarding
choice of location
The following criteria should be taken into account when choosing a location for the invert-
er:
Install only on a solid, non-flammable surface
Max. ambient temperatures:
-40 °C / +55 °C
Relative humidity:
0–100%
The airflow within the inverter is
from the left and right to the top
(cold air taken in from the left and
right, hot air dissipated out of the
top).
The exhaust air can reach a tem-
perature of 70 °C.
100 mm
100 mm
150 mm
-40 °C - +55 °C
0 - 100 %