EasyManuals Logo
Home>Fuji Electric>Inverter>FVR2.2AS1S-7

Fuji Electric FVR2.2AS1S-7 User Manual

Fuji Electric FVR2.2AS1S-7
32 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #13 background imageLoading...
Page #13 background image
6. Specifications
6.1
Single-phase 200 V class series
Item
Specifications
Type
0.4
0.75
1.5
2.2
Applicable motor rating (kW)
*1
0.4 0.75 1.5 2.2
Output Ratings
Rated capacity (kVA)
*2
0.9 1.6 2.8 3.8
Rated voltage (V) *3
Three-phase, 200 to 240 V (with AVR function)
Rated current (A) *4
3.5 (2.5) 4.2 (4.2) 9.2 (7.5) 10.0 (10.0)
Overload capability
150% of rated output current for 1 min (for the rated current given in
parentheses)
Rated frequency (Hz)
50/60 Hz
Input Ratings
Phases, voltage,
frequency
Single-phase, 200 to 240 V, 50/60 Hz
Voltage and
frequency variations
Voltage: +10 to -10%, Frequency: +5 to -5%
Rated
current(A)
*6
(w/o
DCR)
5.4 9.7 16.4 24.0
Required power
supply capacity (kVA)
0.7 1.3 2.4 3.5
Braking
Torque (%) *8
100
50
30
DC braking
Braking starting frequency*9: 0.0 to 60.0 Hz,
Braking time: 0.0 to 30.0 s, Braking level: 0 to 100%
Braking transistor
Built-in
Applicable safety standards
UL61800-5-1, IEC 61800-5-1(under application)
Enclosure
IP20 (IEC 60529), UL open type (UL50)
Cooling method
Fan cooling
Mass (kg)
0.6
0.6
1.0
1.0
*1 Fuji 4-pole standard motors
*2 Refers to the rated capacity assuming the rated output voltage as 220 V.
*3 Output voltages cannot exceed the power supply voltage.
*4 The load shall be reduced so that the continuous operating current is the rated current in parentheses or less if
the carrier frequency is set to 3 kHz or above or the ambient temperature exceeds 40°C.
*
5
Interphase
voltage
unbalance
(%)
=
Max.
voltage
(V)
-
Min.voltage
(V)
×
67
(Refer to
IEC
61800
- 3)
3
phase
average
voltage
(V)
If this value is 2 to 3%, use an optional AC reactor (ACR)
.
*6 Refers to the estimated value to apply when the power supply capacity is 500 kVA (inverter capacity x 10 when
the inverter capacity exceeds 50 kVA) and the inverter is connected to the %X = 5% power supply.
*8 Refers to the average braking torque to apply when the motor running alone decelerates from 60 Hz with the
AVR control being OFF. (It varies with the efficiency of the motor.)
*9 Available only for induction motor drive.