4-2. External output
With using external output function, some status signals are transmitted to the control PCB, and the
related LED lamp indicates the status of this product.
¢
Error status output
Signal on air conditioner error status is generated when a malfunction occurs.
Circuit diagram example
Outdoor unit
control PCB
Example:
Relay unit
Connected unit (Locally purchased)
Example: Fan
Signal
Connector
1
2
1
2
10m*
12 V
On/
Off
P590
On/
Off
PA590
Output voltage (Vcc): DC 12
V 50 mA or less
*: Make the distance from
the PCB to the connected
unit within 10 m.
Error
Normal
On
Off
Error status
Output signal
Optional part
Part name Model name Exterior
External connect kit UTY-XWZXZ3
External output wire