1. Specifications
Type Inverter heat pump
Model name AOYG24KATA
Power supply 230 V ~ 50 Hz
Power supply intake Outdoor unit
Available voltage range 198—264 V
Starting current A 9.7
Fan
Airflow rate
Cooling
m
3
/h
2,885
Heating 2,350
Type × Q'ty Propeller × 1
Motor output W 49
Sound pressure level *1
Cooling
dB (A)
54
Heating 55
Sound power level
Cooling
dB (A)
66
Heating 67
Heat exchanger type
Dimensions
(H × W × D)
mm
Main1: 588 × 881 × 18.19
Main2: 588 × 851 × 18.19
Fin pitch
Main1: 1.3
Main2: 1.3
Rows × Stages
Main1: 1 × 28
Main2: 1 × 28
Pipe type Copper
Fin
Type (Material) Aluminum
Surface treatment PC fin
Compressor
Type × Q'ty DC Twin rotary × 1
Motor output W 1,060
Refrigerant
Type (Global warming potential) R32 (675)
Factory charge g 1,250
Refrigerant oil
Type RmM68AF
Amount
cm
3
400
Enclosure
Material Steel sheet
Color
Beige
Approximate color of Munsell 10YR 7.5/1.0
Dimensions
(H × W × D)
Net
mm
632 × 799 × 290
Gross 692 × 940 × 375
Weight
Net
kg
38
Gross 42
Connection pipe
Size
Liquid
mm (in)
Ø 6.35 (Ø 1/4)
Gas Ø 12.70 (Ø 1/2)
Method Flare
Pre-charge length
m
20
Max. length 25
Max. height difference 20
Operation range
Cooling
°C
-10 to 46
Heating -15 to 24
Drain hose
Material PP
Size mm Ø13.0 (I. D.), Ø16.0 to Ø16.8 (O. D.)
NOTES:
Specifications are based on the following conditions:
Cooling: Indoor temperature of 27 °CDB/19 °CWB, and outdoor temperature of 35 °CDB/24 °CWB.
Heating: Indoor temperature of 20 °CDB/15 °CWB, and outdoor temperature of 7 °CDB/6 °CWB.
Pipe length: 5.0 m, Height difference: 0 m. (Between outdoor unit and indoor unit.)
Protective function might work when using it outside the operation range.
*1: Sound pressure level
Measured values in manufacturer’s anechoic chamber.
Because of the surrounding sound environment, the sound levels measured in actual installation conditions might be higher than the specified values here.
This data is based on EN 14511 standard.
- 68 -
1. Specifications
OUTDOOR UNIT
AOYG24-45KATA
OUTDOOR UNIT
AOYG24-45KATA

Table of Contents

Other manuals for Fujitsu ARXG36KMLA

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu ARXG36KMLA and is the answer not in the manual?

Fujitsu ARXG36KMLA Specifications

General IconGeneral
BrandFujitsu
ModelARXG36KMLA
CategoryAir Conditioner
LanguageEnglish

Related product manuals