Model name ASYG18LFCA ASYG24LFCA ASYG24LFCC
Power supply 1Ø 230 V ~50 Hz
Available voltage range 198—264 V
Capacity kW class 5.0 7.0
Input power W 37 69
Running current A 0.33 0.53
Fan
Airflow rate
Cooling
HIGH
m
3
/h
900 1,120
MED 740 900
LOW 620 740
QUIET 550 620
Heating
HIGH 900 1,100
MED 740 900
LOW 620 740
QUIET 550 620
Type × Q'ty Cross flow fan ×1
Motor output W 42 65
Sound pressure level *
Cooling
HIGH
dB (A)
43 49
MED 37 42
LOW 33 37
QUIET 26 33
Heating
HIGH 42 48
MED 37 42
LOW 33 37
QUIET 25 33
Sound power level
Cooling
dB (A)
58 64
Heating 58 64
Heat exchanger type
Dimensions (H × W × D) mm
Main: 378 × 832 × 26.6
Sub: 84 × 832 × 13.3
Fin pitch mm Main: 1.2, Sub: 1.4
Rows × Stages Main: 2 × 18, Sub: 1 × 4 Main: 2 × 18, Sub: 1 × 4 + 1 × 4
Pipe type Copper tube
Fin type Aluminum
Enclosure
Material Polystyrene
Color
White
(Approximate color of Munsell N 9.25/)
Dimensions
(H × W × D)
Net
mm
320 × 998 × 238
Gross 329 × 1,090 × 420
Weight
Net
kg
14
Gross 18
Connection
pipe
Size
Liquid
mm (in)
Ø6.35 (Ø1/4)
Gas Ø12.70 (Ø1/2) Ø15.88 (Ø5/8)
Method Flare
Drain hose
Material PVC
Size mm Ø12 (I.D.), Ø16 (O.D.)
Operation range
Cooling
°C 18 to 32
%RH 80 or less
Heating °C 16 to 32
Remote controller type Wireless (Wired [option])
NOTES:
• The protective function might work when using it outside the operation range.
• *: Sound pressure level:
– These are the measured values in the manufacturer’s anechoic chamber.
– Because of the surrounding sound environment, the sound levels measured in actual installation conditions might be higher than the specified values here.
DESIGN & TECHNICAL MANUAL
- 18 -
MULTI TYPE
5, 6 ROOMS TYPE