70 Operating Manual
RX1330 M1
Starting up and operation
installing the operating system without the ServerView Installation
Manager" on page 74).
– System already installed:
Ê Press the On/Off button (see figure 7 on page 59).
The server is switched on, performs a system test and boots the
operating system.
Switching the server off
The power-on indicator lights up green (see figure 7 on page 59).
Ê Shut down the operating system properly.
The server is switched off automatically and goes into standby mode. The
AC connected indicator lights up green.
I If the operating system does not switch the server off automatically, press
the On/Off button for at least four seconds and/or send a corresponding
control signal.
Other On/Off options
Besides the On/Off button, the server can be switched ON and OFF in the
following ways:
– Timer-controlled switch-on/off
Using the ServerView Operations Manager or iRMC S4, you can configure
that the server is switched on/off controlled by timer.
– Ring indicator
The server is switched on by an internal or external modem.
– Wake up On LAN (WOL)
The server is switched on by a command via the LAN (Magic Packet
TM
).
– After power failure
The server automatically reboots following a power failure (depending on the
settings in the BIOS or in iRMC S4).