38
10 SECURITY
2.3 LABEL POSITION OF SAFETY MATTERS
These labels warn you of those latent dangers that will possibly cause serious accidents involving
casualties. Please read carefully the words on the labels, the safety warnings and the notes
recounted in the guide. If the labels have fallen off or are illegible, please contact the FX-IG12
agent and change them.
1 Oil level label (Fig. E)
2 Motor switch position ON - OFF (Fig. E)
3 Warning label (Fig. F)
11 OPERATION
11.1 Check before operation
CAUTION: The engine is delivered without oil. Fill in ca. 0.4 liter oil
before starting the engine!
11.1.1 Check the oil level
Using oil without cleanser or 2-strokes engine’s oil may shorten the generator’s service life.
Please use oil containing high quantity of cleanser or use high quality 4-strokes engine’s oil.
The quality level must answer for or exceed the SG/SF level which is required by the American
manufacturer and lay down by American Petroleum Institute.
Please choose the engine oil with proper ropy degree based on the average temperature of the
area you live in. (Fig. G)
To ensure safe operation matters
If you operate the FX-IG12 generator according to the guide, the generator will run safely.
Please read and understand the guide without fail before you use it, or else casualties or
damage of the equip ment will be caused by incorrect operation.
The exhaust contains toxic CO. Do not run the generator in dead-air space. Make sure to
provide enough air.
The fuel is very easy to burn or explode under specific conditions. Turn off the engine before
filling.
When filling the engine, keep away from cigarettes or spark. Please fill in a draught.
Clean the overflowed fuel immediately.
Each time before you start the engine, you must do check it first, avoiding accidents or damage
of the equipment.
The generator must be run at a place at least one meter away from the buildings or other
equipments.
The generator must be run on a horizontal surface. If it leans, the fuel would spill out.
You must master the knowledge of how to turn off the generator quickly, and know all the
operations of controlling the components. Do never operate the engine without correct
instructions.
Children and pets must be kept away from the operating area.
When the engine is running, everyone must keep away from the circumvolving parts.
The generator is a latent danger if it is incorrectly operated, so do not operate it by hand.
Do not operate the generator in the rain or in the snow, preventing wetting it.