24
Fuel Consumption
Estimated fuel supply requirements at half and full load for
natural gas and LP vapor fuels are shown here.
LP Vapor (Propane)
10 kW 8 kW
Full Load
Cu Ft/Hr 65.6 56.4
Gal/Hr (liquid) 1.82 1.57
BTU/Hr 164000 141000
1/2 Load
Cu Ft/Hr 42.8 37.6
Gal/Hr (liquid) 1.18 1.04
BTU/Hr 107000 94000
Exercise
Cu Ft/Hr 23.6 20
Gal/Hr (liquid) 0.65 0.55
BTU/Hr 59000 50000
10 kW 8 kW
Full Load
Cu Ft/ Hr 169 121
BTU / Hr 169000 121000
1/2 Load
Cu Ft/ Hr 111 94
BTU / Hr 111000 94000
Exercise
Cu Ft/ Hr 60 53
BTU / Hr 60000 53000
Recommended Energy
Content of Fuel:
Natural Gas Propane
(LP Vapor)
Heating Value:
BTU per gallon liquid
(gross*)
BTU per Cubic feet
(vapor)
N/A
1,000
91,547
2,500
Natural Gas

Table of Contents

Questions and Answers: