35
Service Manual
Installation and Maintenance
Installation Precaution
Location
How to Install
Incorrect installation of the unit may lead to death, personal injury, or
property damage. Only trained, qualified installers and service personnel
are allowed to install, start-up, and service this equipment. Casualty, injury
or damage due to incorrect installation or installation by unqualified personel
will not be assumed by us.
● Choose a location where there is not any obstacle surrounding the unit.
● Prepare the installation hole a little bigger than the size of the unit.
● Choose the installation space according to the diagrams in Part 3 Outline and Installation Dimension.
1)
2)
3)
Installation
Procedure:
Remove the sticker from the front panel.
Put the unit into the installation hole.
When installing, make sure the unit is slanted downward to the back to
minimize the nosie and vibration of operation. (Slant by 6-10mm.)
(See the right figure)
Make sure the installation place is strong enough to minimize the noise
and vibration of operation.
Fill the gaps in the cabinet with sponge or foam.
Wall
Support
Wooden frame
Rubber plate
Horizontal line
Sunshade baffl
e
Horizontal line
6~10mm
6~10mm
Installation of Accessories:
To install iron support
Make sure the installation hole is strong enough to support the air
conditioner. If not, install an iron support to hold the unit.The iron
support should be fixed on the outside of the building See the
(right figure)
To install sunshade baffle
To avoid dropping anything onto the unit or exposing the unit to direct
sunlight, contact your seller to install a sunshade baffle for the unit. When
installing, make sure the air inlet at the side grille will not be blocked.
Install the unit where:
There is no leakage of inflammable gas.
There is no other heat source or direct sunlight.
It is out of reach of children.
The condensate can be easily drained out.
It is with a minimum distance of 1m away from TV set or any other electric appliance.
Do not install the unit in a laundry, or a bathroom or around a swimming pool, etc.
Consult your seller before installation when the unit is to be installed in an area where salt-laden air prevails(close
to coastal areas, etc), the air contains sulphurous gas (in hot spring zones), or there are other special conditions.
For window type air conditioner with a remote controller, contact your seller when it is to be installed in a place
where there is strong electromagnetic interference.
7. Installation Instructions
.

Table of Contents

Other manuals for GE AEE07KP

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the GE AEE07KP and is the answer not in the manual?

GE AEE07KP Specifications

General IconGeneral
BrandGE
ModelAEE07KP
CategoryAir Conditioner
LanguageEnglish

Related product manuals