31-5000483 Rev. 2 19
Installation Instructions
Capacity Adjustments Instructions for Connect Series
AUH2436ZGDA Default capacity setting of outdoor unit is 36K, AUH4860ZGDA Default capacity setting of outdoor unit
is 60K. Installer will need to change dip switch to 24k when pairing with a 24 indoor AHU OR dip switch to 48K when pairing
with a 48K indoor AHU. Operation Instruction is below:
1. Dip switch settings must be completed before power on the unit.
2. Capacity dip switch is indicated by the red circle below.
Main control Board
Dip Switch Configuration
Model Number Tonnage 1 2 3 4
AUH2436ZGDA 36k (default) ON ON OFF OFF
24k OFF ON OFF OFF
AUH4860ZGDA 60k (default) ON ON OFF OFF
48k OFF ON OFF OFF