49
STATUS CODE
-94
DESCRIPTION
No
MEMORY
RECALL
CONTROL
TYPE
TMM
STATUS CODE
-93
DESCRIPTION
No
MEMORY
RECALL
CONTROL
TYPE
TMM
Figure 1
Figure 1
SYMPTOM
Status code flashes on and off.
POSSIBLE CAUSE
User defined status code is displayed by switch closure or
motor brush sensor closure to negative.
See OEM instruction manual for corrective action
required.
Other Causes:
Terminal 5 and 6 shorted to negative.
Defective input switch (shorted).
Defective TMM card.
NOTE: When SCR pump control is used with internal
TMM function, input terminal is PA1 and PA2 on pump
logic card.
STATUS INDICATION CRITERIA
This status code is displayed when the voltage at
terminal 5 and 6 of TMM is at zero volts.
User defined status code - see OEM instructions manual.
User defined status code - see OEM instructions manual.
SYMPTOM
Status code flashes on and off.
POSSIBLE CAUSE
User defined status code is displayed by switch closure or
motor brush sensor closure to negative.
See OEM instruction manual for corrective action
required.
Other Causes:
Terminal 8 and 10 shorted to negative.
Defective input switch (shorted).
Defective TMM1 card.
NOTE: When SCR pump control is used with internal
TMM function, input terminal is PA4 and PA5 on pump
logic card.
STATUS INDICATION CRITERIA
This status code is displayed when the voltage at
terminal 8 and 10 of TMM is at zero volts.