EasyManuals Logo
Home>GE>Keypad>NetworX NX-1500E

GE NetworX NX-1500E User Manual

GE NetworX NX-1500E
23 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #19 background imageLoading...
Page #19 background image
Page 18
3 ZONE LOW BATTERY - Press the [3] key. The zone light(s) will
illuminate showing which zone(s) has a low battery. This only
applies to wireless zones. Press the [#] key to return to the 1 of 8
service lights.
4 ZONE LOSS OF SUPERVISION - Press the [4] key and the zone
light(s) will illuminate showing which zone(s) has loss of
supervision. This only applies to wireless zones. Press [#] key to
return to the 1 of 8 service lights.
5 ZONE TROUBLE - Press the [5] key and the zone light(s) will
illuminate showing which zone(s) has a trouble condition. Press
the [#] key to return to the 1 of 8 service lights.
TELEPHONE LINE TROUBLE/LINE CUT Press the [6] key. The
zone light(s) will illuminate as they correspond to these service
conditions:
1-5 = Reserved 6 = Telephone Line Trouble / Line Cut
7 = Aux communication device failure
6
The service light will remain lit until the trouble clears and a user
code is entered. * SEE NOTE.
7 FAILURE TO COMMUNICATE - This light will illuminate when
there is a failure to communicate between your system and the
central station. * SEE NOTE.
8 LOSS OF SYSTEM TIME - This light will illuminate when there
has been a loss of power and your system clock needs to be reset.
Instructions are on page 16. * SEE NOTE.
* NOTE to Lights 6,7,8: This fault is global in nature and will affect
all partitions of a multi-partition system.
KEYPAD CONTROL TONES (BEEPS)
A sounder is built into the keypad. If programmed, your system keypad
may sound for any of the following reasons:
Beeps for all keypresses.
Sounds a continuous tone during the Entry delay time.
Pulses when a day zone is violated while the system is disarmed.
Pulses when a FIRE zone has a trouble condition.
Beeps 3 times for trying to arm with the “Ready” light off, if “Force
Arming” has not been selected.