LOC PG DESCRIPTION DEFAULT PROGRAM DATA
L
19 14 DOWNLOAD ACCESS CODE 8-4-8-0-0-0-0-0 _ _ _ _ _ _ _ _
L
20 14 RINGS TO ANSWER DOWNLOAD 8 _
L
21 15 DOWNLOAD CONTROL
Segment 1 (Circle Numbers To Program)
1 = Enables two call answering machine defeat
2 = Enables tone sniff answering machine defeat
3 = Requires callback before downloading
4 = Shutdown control panel
5 = Lock out local programming
6 = Lock out communicator programming
7 = Lock out download section
8 = Enables callback at autotest interval
L
22 15 CALLBACK PHONE NUMBER 14-14-14-14-14-14-14-14-14-14-
14-14-14-14-14-14-14-14-14-14
__ __ __ __ __ __ __ __ __ __
__ __ __ __ __ __ __ __ __ __
L
23 15 FEATURE SELECTION
Segment 1 (Circle Numbers To Program)
1 = Quick Arm
2 = Re-Exit
3 = Auto Bypass
4 = Silent Panic
5 = Audible Panic
6 = Auxiliary 1
7 = Auxiliary 2
8 = Multi Keypress Tamper
Segment 2 (Circle Numbers To Program)
1 = LED extinguish enable
2 = Require user code for bypassing zones
3 = Bypass sounder alert
4 = AC power/low battery sounder alert
5 = Enables bypass toggle
6 = Enables silent auto arm
7 = Enables automatic instant
8 = Enables Instant mode toggle
Segment 3 (Circle Numbers To Program)
1 = Open/Close
2 = Bypass
3 = Restore
4 = Trouble
5 = Tamper
6 = Cancel
7 = Recent Closing
8 = Exit Error
Segment 4 (Circle Numbers To Program)
1 = Late to Close / Early to Open
2 = Auto Arm in Stay Mode
3 = Disables door delays in Night mode
4-8 = Reserved
Segment 5 RESERVED
L
24 16 ENTRY / EXIT TIMERS
Segment 1 (Entry Time 1) 30
Segment 2 (Exit Time 1) 60
Segment 3 (Entry Time 2) 30
Segment 4 (Exit Time 2) 60
Segments 5 & 6 Reserved
L
25 17 ZONES 1-8, ZONE TYPES 3-5-6-6-6-6-6-6 _ _ _ _ _ _ _ _
29-36 17 RESERVED
L
37 17 SIREN AND SYSTEM SUPERVISION
Segment 1 (Circle Numbers To Program)
1 = Siren sounds for telephone line cut while armed.
2 = Siren sounds for telephone line cut while disarmed.
3 = Siren blast at arming.
4 = Siren blast at exit delay expiration.
5 = Siren blast at closing kissoff.
6 = Siren sounds during a cross-zone verification time.
7 = Siren sounds for a tamper.
8 = Siren blast one time for keyswitch arming, two times for disarming.
(Note: Must be disabled for SIA CP-01
installations.)
Segment 2 (Circle Numbers To Program)
1 = Convert siren driver to voltage out.
2 = Siren sounds for expander trouble (required for U.L.).
3 = Immediate Restore by zone.
4 = Dynamic battery test performed upon arming.
5 = Battery missing test performed every 12 seconds.
6 = Manual bell test performed during [
r
]-[4]-[4] test function.
7 = Manual communicator test performed during [r]-[4]-[4] test function.
8 = Box tamper enabled.