30
NX-4V2 Control
LOC PG DESCRIPTION DEFAULT PROGRAM DATA
L
37 17 Segment 3 (Circle numbers to program)
1 = Box Tamper report enabled.
2 = AC Fail report enabled.
3 = Low Battery report enabled.
4 = Auxiliary power over current report enabled.
5 = Siren supervision report enabled.
6 = Telephone Line Cut report enabled.
7 = Reserved.
8 = Expander trouble report enabled.
Segment 4 (Circle Numbers To Program)
1 = Failure To Communicate report enabled.
2 = Log Full report enabled.
3 = Autotest report enabled.
4 = Start and End Programming report enabled.
5 = End Download report enabled.
6 = Sensor Low Battery report enabled.
7 = Sensor Missing report enabled.
8 = First to Open / Last to Close
Segment 5 (Circle numbers to program)
1 = Lost Clock service LED enable.
2 = Zone Doubling enable.
3 = Disable on-board 4 zones.
4 = Enables two trips on the same cross-zone to activate the alarm.
5 = Disables bypass reports for force armed zones
6 = Reserved.
7 = Clock uses internal crystal.
8 = Disable Temporal Siren on Fire (Do not disable on UL listed systems)
Segment 6 (Circle numbers to program)
1 = Reserved.
2 = Reserved.
3 = Enable Zone Activity in Hours (not Days)
4 = Enable Daylight Savings Time (DST)
5 = Reserved
6 = Disable Clean Me report
7 = Disable Start/End Test report
8 = Reserved
Segment 7 - RESERVED
L
38 18 SWINGER SHUTDOWN COUNT 1 _
L
39 18 KEYPAD SOUNDER CONTROL
Segment 1 (Circle numbers to program)
1 = Keypad sounds for Telephone Line Cut when in the Armed state.
2 = Keypad sounds for Telephone Line Cut when in the Disarmed state.
3 = Keypad sounds upon AC Power Failure.
4 = Keypad sounds upon Low Battery Detection.
5 = Keypad sounds during Cross Zone Trip Time.
6 = Keypad sounds for Tamper Alarm.
7 = Reserved.
8 = Keypad sounds for expander trouble (required for UL).
L
40 19 SYSTEM TIMERS
Segment 1 Dynamic Battery Test duration (0-255 minutes) 0 _
Segment 2 AC Failure report delay (0-255 minutes) 5 _
Segment 3 Power Up Delay (0-60 seconds) 60 _
Segment 4 Siren Time (1-254 minutes) 8 _
Segment 5 Telephone Line Cut delay (0-255 seconds) 0 _
Segment 6 Cross Zone Time (0-255 minutes) 5 _
Segment 7 Chime Time in 50 mS increments (0-255) 3 _
Segment 8 Dialer delay (15-255 seconds) 30 _
Segment 9 Fire Alarm Verification Time (120-255 sec.) 0 _
Segment 10 Listen-In Time (0-255 seconds) 0 _
Segment 11 Zone Monitor Timer (0-255 Days) 0 _
Segments 12 – 14 Reserved
41 19 SPECIAL FEATURES
Segment 1 (Circle numbers to program)
1 = Enables 6-digit code option. All arm/disarm/Go To Program codes require six digits.
2 = Requires valid user code entry for [r]-[9]-[8] and [r]-[9]-[9] functions to work.
3 = Enable Auto Cancel / Abort.
4 = Enable Walk-Test Mode.
5 = Enables Auto Force-Arming with keyfob or keyswitch.
WWW.DIYALARMFORUM.COM