2.15.7 Troubleshooting the Autoflush Timer
14
PROBLEM: Days are flashing, pressing any Key does nothing except
“Hand” Key turns output ON and OFF.
SOLUTION: Time of Day and Day of Week have not been set.
See Section 2.15.3 (Setting-Up the Autoflush Timer Clock).
PROBLEM: Time of day was set while holding the Clock Key down, but
days are still flashing.
SOLUTION: Current day of week was not set while holding down
the Clock Key. See Setting-Up the Autoflush Timer Clock
(Section 2.15.2).
PROBLEM: It is 10
A.M. and a ON program for 8 A.M. was entered, but
the output is not ON.
SOLUTION: The ON or OFF was not entered as part of the program.
ON or OFF must be selected.