Dichiarazione di conformità CE
Il fabbricante:
Gi.Bi.Di. Continental S.p.A.
Sede Legale :
Via B.Bonomi, 17 Fraz. Toline 25055 Pisogne (BS)
Sede Amministrativa-Ufficio Commerciale-Stabilimento :
Via Abetone Brennero, 177/B, 46025 Poggio Rusco (Mantova) ITALY
Tel. 0039 0386 522011 - Fax Uff.comm 0039 0386 522031
Dichiara che i prodotti:
Sono conformi alle seguenti Direttive CEE:
•Direttiva Bassa Tensione 73/23 e successive modifiche;
•Direttiva Compatibilità Elettromagnetica 89/336 e successive modifiche;
•Direttiva
e che sono state applicate le seguenti norme armonizzate:
Data 13/04/06
Firma Ammistratore Delegato
Dario Gualeni
APPARECCHIATURA ELETTRONICA SC24
R&TTE 99/05
! EN60335-1, EN300 220-3, EN301 489-1, EN301 489-3
! EN61000-3-2, EN61000-3-3, EN61000-6-3, EN61000-6-1
SC248
I
TECHNICAL SPECIFICATIONS
•Red warning LEDs of N.C. contacts (photo, safety dev, fcc, fca, stop).
•Green warning LEDs of N.O. contacts. (start, ped).
•Safety tests run before the opening and closing movements.
•Deceleration during opening and closing controlled by 2 supplementary magnets to be fitted in the desired position
at a minimum distance of at least 400 mm with respect to those used as limit switch (Fig.2). Deceleration is
adjustable with a trimmer (SLOW).
•Stop and motion inversion for 2 seconds after intervention of the safety devices. At the next Star t pulse the motion
restarts in the obstacle freeing direction.
•Amperometric reading of motor absorption for the anti-crushing function both during normal operation and in slow
motion. (adjustable with AMP.FORCE and AMP.SLOW trimmers). The amperometric intervention determines
stopping and motion inversion for 2 seconds. At the next Start pulse the motion restar ts in the obstacle freeing
direction.
•Pedestrian operation with fixed opening of 10 seconds. The condominium function and automatic closing are
always enabled.
•Provision for use with buffer batteries (accessory battery charger board)
•Test of battery charge status. During battery operation, an acoustic signal synchronised with the flashlight will be
activated. When the batteries are nearly flat and an opening command is given, the gate will open and remain thus.
Should the batteries not be sufficiently charged, the gate will not open.
SAFETY DEVICE POWER SUPPLY. Connection to this power supply allows TESTING the devices before motion. The
safety devices must be connected to this terminal and will be powered only during the operating cycle.
FEATURES / FUNCTIONS
UK
SC24
9
Control unit SC24
Type
Electronic control unit for automation of a sliding gate with
24Vdc motor
Power supply 230Vdc single-phase 50/60 Hz
No. of motors 1
Motor power supply 24Vdc
Flashlight 24Vdc 10W max
Warning light 24Vdc 3W max
Accessory power supply 24Vdc 8W max including safety device power supply
Safety device power supply 24Vdc 8W max including accessory power supply
Plug-in Radio receiver
Operating temperature -20°C +60°C
Run time 240 sec. fixed
Pause time Adjustable between 2 and 215 sec.
Recommended battery type Rechargeable lead battery 24V 2Ah (2 x 12V 2Ah)