Programming a new wash program 38
Code 429159
Rev. 15/0717
Main use options
Connection of a water inlet
other than Water 1 and
Water 2 inlets.
From AS recovery tank.
Water intake from third inlet
Water intake from AS recovery tank
Temperature programmed in this phase: NO
Water intake from third inlet
Water intake from AS recovery tank
Water mixture from third inlet and hot water
depending on the temperature programmed
Connection to cold water
supply
NON programmable
Opens simultaneously with Cold Water (refer to
water inlet programming chart)
Connection to hot water
supply
NON programmable
Opens simultaneously with Hot Water (refer to
water inlet programming chart)
Using the third water inlet requires:
option previously installed in the washing machine.
configured as a separate inlet in the SETUP menu.
7.3.2. Bath level
This function only appears if the water inlet has been programmed.
Modifying the value of levels is possible in the CONFIGURATION menu.
Possible programming
Level L1
Minimum programmable level
Level L3
<<< Option programmed by default
Level L6
Maximum programmable level
7.3.3. Bath temperature – Heating
Water mixture: in washing machines supplied with hot and cold water, the washer opens the two inlets
alternatively until it reaches the programmed temperature, provided that the hot water temperature enables it.
When the programmed water temperature is lower than 35ºC / 95F, the two valves open simultaneously.
Programmable range in ºC: 0 – 90
Programmable range in ºF: 32 – 194
Value programmed by default: 0ºC / 32F
Steam or electric heating option
Heating connection: Washing machines with steam or electric heating systems duly activated in the SETUP
menu. The heating will be connected while the bath temperature is below the phase programmed temperature.
The heating system will not be connected if the bath level inside the washing machine has not reached the set
safety level.