Go Power! TS-30
Owner’s Manual
5
2.5.2 INSTALLATION BETWEEN INVERTER AND ALTERNATING
SOURCE (CONFIGURATION C)
1. For installation between inverter (default) and another power supply (dominant),
such as the output from a prior power cord/ generator transfer switch. These
connections will allow any other supply to dominate the inverter, and the inverter
output will pass through the normally closed contacts of the switch. This allows
the inverter to operate only in the absence of the other power supplies, which is
ideal for inverters.
2. Connect the inverter to terminals 7 and 8, and connect the other power supply
to 5 and 6. Output terminals always remain the same.
3. Set the timer delay bypass switch of the inverter/alternate source transfer switch
to the ON position. See Diagram 2.
Diagram 2 – Typical Generator inverter / Alternate Source Connection
To
panel
Hot
Hot
Neutral
Neutral
Ground
From
Alternate
Source
Neutral
From
Alternate
Source Hot
Switch
Priority
Override
Mode:
Generator
Default
C
30 Amp System
Powercord
Generator
Inverter