User Manual V1.4-2022-08-30 03 Product Introduction
3.4 Features
For a safe operation, the inverter will automatically reduce the output power when the operating
environment is not ideal.
The following are the factors that may occur power derating. Please try to avoid them when the
inverter is working.
Unfavorable environmental conditions, e.g., direct sunlight, high temperature, etc.
Inverter's output power percentage has been set.
Over-frequency derating.
Higher input voltage value.
Higher input current value.
Power Derating
Reserved port for earth fault alarm.
Once an earth fault occurs, the LED indicator will light up. And the system will email the fault
information to the customer. Install the inverter in a high trac area where the indicators would
be noticed.
Earth Fault Alarm

Other manuals for Goodwe EH Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Goodwe EH Series and is the answer not in the manual?

Goodwe EH Series Specifications

General IconGeneral
TypeHybrid Inverter
Number of MPPTs2
THDi<3%
DC SwitchIntegrated
Protection DegreeIP65
Max. Charging/Discharging Power5kW
Battery Voltage Range40V to 60V
Nominal AC Voltage230V
Operating Temperature Range-25°C to 60°C
Cooling MethodNatural Convection
CommunicationRS485
Battery TypeLithium
AC Output Voltage230V
AC Output Frequency50/60 Hz