10 Technical Parameters User Manual V1.4-2022-08-30
Technical Data GW3600N-EH GW5000N-EH GW6000N-EH
Battery Input Data
Battery Type Li-Ion
Nominal Battery Voltage (V) 350
Battery Voltage Range (V) 85~460
Max. Continuous Charging Current (A) 25
Max. Continuous Discharging Current
(A)
25
Max. Charge Power (W) 6,000
Max. Discharge Power (W) 3,600 5,000 6,000
PV String Input Data
Max. Input Power (W) 5,400 7,500 9,000
Max. Input Voltage (V) 580
MPPT Operating Voltage Range (V) 100~550
MPPT Voltage Range at Nominal
Power (V)
150~550 210~550 250~550
Start-up Voltage (V) 90
Nominal Input Voltage (V) 380
Max. Input Current per MPPT (A) 16
Max. Short Circuit Current per MPPT
(A)
21.2
Max. Backfeed Current to The Array
(A)
0
Number of MPP Trackers 2
Number of Strings per MPPT 1
AC Output Data (On-grid)
Nominal Apparent Power Output to
Utility Grid (VA)
3,600 5,000 6,000
Max. Apparent Power Output to Utility
Grid (VA)
3,600 5,000 6,000
Nominal Apparent Power from Utility
Grid(VA)
7,200 10,000 12,000
10.2 Technical Parameters - Belgium

Other manuals for Goodwe EH Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Goodwe EH Series and is the answer not in the manual?

Goodwe EH Series Specifications

General IconGeneral
BrandGoodwe
ModelEH Series
CategoryInverter
LanguageEnglish

Related product manuals