48
10 Technical Parameters
User Manual V1.1-2022-07-20
Technical Data GW100K-HT GW110K-HT GW120K-HT GW136K-HTH
Input
Max.Input Power (kW) 150 165 180 205
Max.Input Voltage (V) 1100 1100 1100 1100
MPPT Operating Voltage Range
(V)
180~1000 180~1000 180~1000 180~1000
MPPT Voltage Range at Nominal
Power (V)
500~850 500~850 500~850 500~850
Start-up Voltage (V) 200 200 200 200
Nominal Input Voltage (V) 600 600 600 750
Max. Input Current per MPPT (A) 30 30 30 30
Max. Short Circuit Current per
MPPT (A)
45 45 45 45
Max. Backfeed Current to The
Array (A)
0 0 0 0
Number of MPPT 10 12 12 12
Number of Strings per MPPT 2 2 2 2
Output
Nominal Output Power (kW) 100
*1
110 120 136
Nominal Output Apparent Power
(kVA)
100
*
1 110 120 136
Max. AC Active Power (kW) 110
*1*4
121
*4
132
*4
150
*4
Max. AC Apparent Power (kVA) 110
*1*5
121
*5
132
*5
150
*5
Nominal Power at 40°C(kW) 100 110 120 136
Max Power at 40°C(Including AC
Overload) (kW)
110 121@400V 132@400V 150
Nominal Output Voltage (V) 400, 3L/N/PE or 3L/PE
*2
500 , 3L/PE
Output Voltage Range (V) 320~440 425~550
Nominal AC Grid Frequency (Hz) 50 / 60 50 / 60 50 / 60 50 / 60
AC Grid Frequency Range (Hz) 45~55/55~65
Max. Output Current (A) 167.0 175.5 191.3 173.2
Max. Output Fault Current (peak
and duration) (A)
364@5μs 364@5μs 364@5μs 364@5μs