15
Technical Information
Service Manual
2.3 Cooling and Heating Data Sheet in Rated Frequency
Instruction:
T1: Inlet and outlet pipe temperature of evaporator
T2: Inlet and outlet pipe temperature of condenser
P: Pressure at the side of big valve
Connection pipe length: 24.6ft.
Cooling:
Heating:
Rated cooling condition(°F)
(DB/WB)
Model
Pressure of gas pipe connecting
indoor and outdoor unit
Inlet and outlet pipe temperature of
heat exchanger
Fan speed of
indoor unit
Fan speed of
outdoor unit
Indoor Outdoor P (MPa) T1 (°F) T2 (°F)
80/66.9 95/- 09K 0.9~1.1 53.6 to 57.2 158 to 104 Super High High
80/66.9 95/- 12K 0.9~1.1 53.6 to 57.2 158 to 104 Super High High
80/66.9 95/- 18K 0.9~1.1 53.6 to 57.2 176 to 104 Super High High
80/66.9 95/- 24K 0.9~1.1 53.6 to 57.2 176 to 104 Super High High
2.4 Noise Curve
Heating
Indoor side noise when blowing
Indoor fan motor rotating speed
Noice/dB(A)
25
30
35
40
45
SS HMHM ML LSLSM
Cooling
20
Rated heating condition(°F)
(DB/WB)
Model
Pressure of gas pipe connecting
indoor and outdoor unit
Inlet and outlet pipe temperature of
heat exchanger
Fan speed of
indoor unit
Fan speed of
outdoor unit
Indoor Outdoor P (MPa) T1 (°F) T2 (°F)
70/- 19.94/19.04 09K 2.2~2.4 158 to 95 35.6 to 39.2 Super High High
70/- 19.94/19.04 12K 2.2~2.4 158 to 95 35.6 to 39.2 Super High High
70/- 19.94/19.04 18K 2.5~2.7 158 to 104 33.8 to 41.0 Super High High
70/- 19.94/19.04 24K 2.5~2.7 158 to 104 33.8 to 41.0 Super High High
Heating
Indoor side noise when blowing
Indoor fan motor rotating speed
Noice/dB(A)
25
30
35
40
45
SS HMHM ML LSLSM
Cooling
20
Heating
Indoor side noise when blowing
Indoor fan motor rotating speed
Noice/dB(A)
35
40
45
SS HMHM ML LSL
Cooling
50
55
09K
18K
12K
24K
2. Specications
Heating
Indoor side noise when blowing
Indoor fan motor rotating speed
Cooling
20
25
30
35
40
45
50
SS HMHM ML LSLSM